Control Box
8 Ounce Pressure Setting
Narrow Your Results
Mfr / Trade Name
Category - Main
TLS Consoles & Installed Modules
Replacement Parts & Spare Modules
Submersible Pumps, Motors & Leak Detectors
Valves, Drop Tubes & Vents
Fiberglass
Semi-Rigid
Type
Composition
Size
- List View
- Gallery View
Page of 2 |

3 Inch X 2 Inch Reducer Bushing Scarfed O.D. X Taper I.D.
Item No. 012030-231-7
UL 971 listed

4 Inch X 3 Inch Concentric Reducer (2 Piece)
Item No. 012040-238-3
UL971 listed and also available in 5 inch x 4 inch

5 Inch X 4 Inch Concentric Reducer (2 Piece)
Item No. 012050-238-3
UL971 listed and also available in 4 inch x 3 inch

8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244O-0600AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

8 Inch Female NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244O-0600AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

6 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0050AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

8 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

10 Inch Flanged 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OF-0400AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

3 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0050AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

4 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0100AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

6 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0200AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

8 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton A O-Ring UL 2583 And ULC Listed
Item No. 244OM-0600AV
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

8 Inch Male NPT 8 Ounce/Square Inch Aluminum Emergency Vent With Cast Iron Cover And FKM Viton B O-Ring EVR Approved UL 2583 And ULC Listed
Item No. 244OM-0600AVEVR
UL Listed emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over-pressurized and possibly rupturing if ever exposed to fire.

Adjustable Functional Element For AG Pumps
Item No. 323-002-5
Repair part for Red Jacket submersible turbines

3 Inch X 2 Inch Primary Reducer Bushing
Item No. 32370504
Proven reliable fiberglass pipe system

3 Inch X 2 Inch Secondary Containment Reducer With 3/4 Inch Test Port (2 Piece)
Item No. 32387604
Proven reliable fiberglass pipe system

3 Inch X 2 Inch Containment Reducer Ring (3 Piece Combo)
Item No. 32469208
Installs in one half the time of conventional fiberglass pipe

TLS-450 Continuous Statistical Leak Detection - Installed
Item No. 332972-006
CSLD tank testing software enhancement for TLS-450 console

4 Inch x 3 Inch Primary Reducer Bushing
Item No. 43370504
Proven reliable fiberglass pipe system

4 Inch X 3 Inch Secondary Containment Reducer (2 Piece)
Item No. 43387603
Proven Reliable Fiberglass Pipe System